Your location: Technical>>Troubleshooting
Not Start
Liter
|
Reason |
Excluded |
Voltage is too low |
Check the motor load when working starter potential. Voltage fluctuationrange allows ± 10% |
|
Motor does not turn |
Check motor and circuit |
|
Motor Rewind |
Any change in the two-phase three-phase line |
|
Motor phase (the motor does not move, and there isbuzz) |
Check the circuit breakers and electrical wiring |
|
Lowering valve open |
Button is released in the fall state, check with a voltmeter lowering valvehas power. If not, then check the wiring and troubleshooting; if there is power, check the drop valve itself fails, or replace lowering valve. Lowering valve lubricant must be kept clean, and the mobile and flexible. |
|
Low pressure relief valve |
Re-adjust the relief valve. At 100% of rated load adjustment |
|
Oil level is too low, thepump suction air |
Fill the hydraulic oil |
|
Suction filter blocked |
Clean the filter |
|
Oil leak paragraph |
Check the suction pipe and fittings, tighten the connector, if necessary,replace the connector. |
|
Overload |
Reduce the load, non-overloading use. |
|
From However Next
Drop
|
Discharge check valve |
Check valve one-way valve. If you find that the check valve sealing surfaceof stolen goods, cleaning the check valve. |
Lowering valve closed lax |
Check the lowering valve has power. If there is power then check the dropdown valve itself is faulty or replace the valve. Lowering valve lubricantmust be kept clean, and the mobile and flexible. |
|
Drain the fuel tank |
Replace cylinder seals |
|
Not Next
Drop
|
Lowering valve failure |
Press the down button on the case, check the lowering valve has power.Without electricity, trying to exclude; if electric, check the drop down valve itself is faulty or replaced valve. Lowering valve should be kept cleanlubrication. |
Lowering speed control valve disorders |
Adjust lowering speed control valve, such as mediation fails, replace thenew valve. |